LCD Brightness (ex factory 220)
Select «Extended basic settings»!
The
button can be used to alter the brightness or
type on the display.
LCD Contrast (ex factory 26)
Select «Extended basic settings»!
The
button can be used to alter the contrast on
the display.
Alarm volume (ex factory VOLUME 2)
Select «Extended basic settings»!
With the Alarm setting switched on, a signal sounds at
regular intervals at the end of the programme. The level
can be adjusted in 3 levels using the
button.
Off
Volume 1
Volume 2
Volume 3
Standby function (ex factory ON)
Select «Extended basic settings»!
When the standby function is switched on, the controls
switch off when wash programme is running or laundry
weighing is carried out in energy saving mode.
All displays are dark.
Optical interface (ex factory OFF)
Select «Extended basic settings»!
If the optical interface (SCS) is switched on, customer
services can communicate with the machine by PC.
Reduced mains power (ex factory OFF)
Select «Extended basic settings»!
If the connected load is reduced, the programme times
will be extended accordingly.
9080/9100/9120
Off = 400V 3N ~ 9,8 kW / 16AT
On = 400V 2N ~ 6,8 kW / 16AT
Off = 230V 3 ~ 9,8 kW / 25AT
9130
Off = 400V 3N ~ 14,9 kW / 25AT
On = 400V 2N ~ 10,0 kW / 25AT
Off = 230V 3 ~ 14,9 kW / 40AT
9160
Off = 400V 3N ~ 18,0 kW / 32AT
On = 400V 2N ~ 12,0 kW / 32AT
Off = 230V 3 ~ 18,0 kW / 50AT
Wash Programme Set (ex factory GASTRONOMY)
Select «Extended basic settings»!
One of the six programme groups can be selected using
the button
.
GASTRONOMY
HOMES
COMM COMPANY
FACILITY CLEANER
WET CLEANING
FIRE BRIGADE
Default language (ex factory DEUTSCH)
Select «Extended basic settings»!
If another language is temporarily selected via the
buttons
and , 4 minutes after programme end,
in stand by mode or after a long standstill, the setting
reverts back to the default language.
Door opening at programme end (ex factory OFF)
Select «Extended basic settings»!
If this function is switched on, the door will open auto-
matically at the end of the programme.
Start time preselection (ex factory 24 HOURS)
Select «Extended basic settings»!
The maximum adjustable range of the start time delay
can be reset from 24 hours to 100 hours.